A multi-function environment meter that combines the functions of a sound level meter, light meter, humidity meter and temperature meter. Typical sound applications include checking acoustics of recording studios, auditoriums and professional hi-fi installations. The light and humidity meters are ideal for video photographers, greenhouse and hydroponic setups, etc. Others who should find this meter essential include interior designers, factory and office managers, record and archive keepers, schools, hospitals, laboratories and, of course, universities.
Features:
• Sound level meter
• Light level meter
• Indoor temperature and humidity measurement
• Non contact voltage
• Display: 4000 count
• Safety Category: Cat IV 600V
• Basic DCV accuracy: 1%
• Temperature: -20°C to 750°C (±1.2%)
• Ave/RMS: Ave
• Input impedance: 10M
• Special features: Lux, SPL, Humidity
Digital Multi-Meter
| Count Maximum Reading | 4.0 count |
|---|
Meter
| Meter Input Impedence | 10.0 Ω |
|---|
| Input Protection Fuse | 500.0mA,10.0mA |
|---|
| Casing | Plastic |
|---|
Power from disposable battery
| Size / Shape | 9V |
|---|
| Battery quantity | 1.0 pc |
|---|
| Compartment location | Internal / In-built |
|---|
| How is battery compartment kept closed | Clip and Screw |
|---|
Meter Safety Rating
| Safety Category | Cat IV |
|---|
| Safety Rating Max Volt | 600.0 V |
|---|
Meter Probes
| Probe rating voltage | 600.0 V |
|---|
| Probe safety rating | Cat IV |
|---|
Measures Voltage AC
| AC Voltage Ranges | 400.0mV,4.0V,40.0V,100.0V,250.0V |
|---|
| AC Voltage Accuracy | 1.2 % |
|---|
Measures Voltage DC
| DC Voltage Ranges | 400.0mV,4.0V,40.0V,100.0V,250.0V |
|---|
| DC Voltage Accuracy | 0.5 % |
|---|
Measures Current AC
| AC Current Ranges | 400.0µA,4.0mA,40.0mA,400.0mA,10.0A |
|---|
| AC Current Accuracy | 1.0 % |
|---|
Measures Current DC
| DC Current Ranges | 400.0µA,4.0mA,40.0mA,400.0mA,10.0A |
|---|
| DC Current Accuracy | 1.0 % |
|---|
Measures Resistance
| Resistance Ranges | 400.0Ω,4.0kΩ,40.0kΩ,400.0kΩ,4.0MΩ,40.0MΩ |
|---|
| Resistance Accuracy | 0.8 % |
|---|
Measures Capacitance
| Capacitance Ranges | 50.0nF,500.0nF,5.0µF,50.0µF,100.0µF |
|---|
| Capacitance Accuracy | 3.5 % |
|---|
Measures Frequency
| Frequency Ranges | 5.0Hz,50.0Hz,500.0Hz,5.0kHz,500.0kHz,10.0MHz |
|---|
| Frequency Accuracy | 1.5 % |
|---|
Measures Continuity
| Continuity indicator | Needle |
|---|
Measures Temperature
| Outdoor / Exterior Scale | -20.0°C-750.0°C |
|---|
| Celcius Accuracy | 1.2 % |
|---|
Product Dimensions
| Length | 170.0 mm |
|---|
| Width | 75.0 mm |
|---|
| Depth | 48.0 mm |
|---|
Packaged Dimensions